IR-10
To limit pressure in a system. Pressure acting fast, this valve is suitable for fixed flow. Good for continuous duty and accurate pressure control with constant or varying flows.
The adjustable spring-loaded cone is shifted at valve setting by pressure on port 1 allowing relief flow to port 2. Reverse flow, port 2 to port 1 is blocked. Back pressure on port 2 adds to the valve setting.
Rated Flow :
40 l/min
Max. Pressure :
350 bar
Working temperature :
Min. -20℃ , Max. 90℃ , with standard BUNAN gaskets
Min. -20℃ , Max. 120℃ , with optional VITON gaskets on request
Fluid :
best use mineral oil with viscosity ranging between 10 and 200 cSt
Filter :
25 micron or better
Cavities :
see cavity data 10-02
Installation :
before screwing the cartridge on the valve body, ascertain to provide suitable gasket lubrication with clean oil and also be sure to screw the cartridge manually in to reach against the gaskets in the valve body.